Coagulation Diagnosis in Optimal Match
In order to provide our customers with an efficient and user-friendly overall solution we carry a product range of hemostasis reagents perfectly matching our analysis systems.
The SYCOmed range of coagulation diagnostics includes reagents for global tests such as PT (Quick), aPTT, fibrinogen and thrombin time as well as the matching control and calibration plasmas.
Product | Description | Size | Cat No. | |
---|---|---|---|---|
PT, Prothrombin Time, Quick | ||||
PT-S | Thromboplastin, Rabbit brain extract, dried, ISI~1.0 | 10 x 4 ml | TE0140 | |
PT-S | Thromboplastin, Rabbit brain extract, dried, ISI~1.0 | 10 x 10 ml | TE0100 | |
Prothrombin Time Kit for determination of whole blood PT (Owren) | Whole blood PT (Owren) ISI~1.0 Thromboplastin, Rabbit brain extract, dried Diluent CaCl2 0,025 M | 5 x 10 ml 5 x 5 ml 5 x 5 ml | TE0250 | |
Owren's Puffer | Dilution of blood plasma samples | 1 x 100 ml | TE9100 | |
aPTT, Activated Partial Thromboplastin Time | ||||
aPTT-S | Liquid, contains colloidal silicate with phospholipids | 10 x 5 ml | TE0350 | |
Calcium Chloride 0,025 M | for use with aPTT-S | 10 x 5 ml | TE9050 | |
FIB, Fibrinogen | ||||
Fibrinogen | Bovine Thrombin, dried | 10 x 2 ml | TE0420 | |
Fibrinogen | Bovine Thrombin, dried | 10 x 5 ml | TE0450 | |
IBS Puffer | Imidazolpuffer, Diluent of Fibrinogen and Factor Tests | 1 x 125 ml | TE9002 | |
Thrombin Time, TT | ||||
Thrombintime | Bovin Thrombin, dried | 10 x 2 ml | TE0520 | |
Deficient Plasma | ||||
Factor II | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4002 | |
Factor V | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4005 | |
Factor VII | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4007 | |
Factor VIII | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4008 | |
Factor IX | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4009 | |
Factor X | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4010 | |
Factor XI | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4011 | |
Factor XII | Deficient Plasma, depleted human plasma, dried | 10 x 1 ml | TE4012 | |
Calibrator, Reference Plasma | ||||
Calibrator, Reference Plasma | Human Reference plasma for PT, aPTT, TT, FIB, Factors, dried | 5 x 1 ml | TE8050 | |
Control Plasma | ||||
Control plasma Normal | normal control for PT, aPTT, TT, FIB, dried | 10 x 1 ml | TE8001 | |
Control plasma Abnormal | abnormal control for PT, aPTT, TT, FIB, dried | 10 x 1 ml | TE8002 | |
Control plasma Abnormal PLUS | abnormal control for PT, aPTT, TT, FIB, Factors , PC, PS, AT, DD, dried | 10 x 1 ml | TE8003 |